hopcalite catalysts, as highly efficient room-temperature CO purification materials, often deactivate rapidly in practical applications due to problems such as water vapor and carbonate deposition, leading to decreased purification efficiency and soaring replacement costs. This article analyzes its deactivation mechanism in depth and clearly points out that heating regeneration is a simple, low-cost, and effective regeneration method: for water poisoning, heating at 100-130℃ for 4-10 m